Switching/Forwarding delay | Short forwarding delay: The 100 Mbit/s Ethernet port sends the 64-byte Ethernet packets at a delay shorter than 20 μs. |
BER in full load | BER of port when transmitting data in full load < 10 e-7 |
System performance | |
System | Redundant configuration |
System availability in typical configuration | >99.999% |
Mean Time Between Failures (year) | ≈45 |
Configuration | |
Maintenance port | Number of 10 Mbit/s/100 Mbit/s maintenance Ethernet ports: 1 |
Number of serial ports for local/remote maintenance: 1 | |
Monitoring port | Number of environment monitoring serial ports: 1 |
Maximum number of GPON ports in a subrack | ETSI Chassis: 256 |
Maximum number of 10G GPON ports in a subrack | ETSI Chassis: 128 |
Maximum number of P2P FE ports in a subrack | ETSI Chassis: 768 |
Maximum number of P2P GE ports in a subrack | ETSI Chassis: 768 |
Maximum number of upstream ports (GE ports in the GIU slot) in a subrack | 8 |
Maximum number of upstream ports (10GE ports in the GIU slot) in a subrack | 4 |
Maximum number of ADSL2+ ports in a subrack | ETSI Chassis:1024 IEC Chassis:896 |
Maximum number of VDSL2 ports in a subrack | ETSI Chassis:1024 IEC Chassis:896 |
Maximum number of EFM SHDSL ports in a subrack | ETSI Chassis:512 IEC Chassis:448 |
Maximum number of TDM SHDSL ports in a subrack | ETSI Chassis:256 IEC Chassis:224 |
Maximum number of POTS ports in a subrack | ETSI Chassis:1024 IEC Chassis:896 |
Maximum number of ISDN BRA ports in a subrack | ETSI Chassis:256 IEC Chassis:224 |
Maximum number of ISDN PRA ports in a subrack | ETSI Chassis:64 IEC Chassis:56 |
Management ports | |
Outband management Ethernet port (RJ-45) | SCUB/SCUN/SCUF/SCUH control board: 1 Port Per Board |
Local serial port (Console) | SCUB/SCUN/SCUF/SCUH control board: 1 Port Per Board |
Upstream ports | |
GE electrical port | GICE: 4 Ports Per Board |
GICG: 2 Ports Per Board | |
GE optical port | GICF/GICK: 2 Ports Per Board |
SCUB/SCUN/SCUH/GICD/GSCA: 4 Ports Per Board | |
ETHB/SPUA/SPUF: 8 Ports Per Board | |
SPUC: 40 Ports Per Board | |
10GE optical port | X2CS/SPUA: 2 Ports Per Board |
SPUC: 4 Ports Per Board | |
SPUF: 8 Ports Per Board | |
E1 port | TOPA: 16 Ports Per Board |
STM-1 upstream optical port | TOPA: 2 Ports Per Board |
PON upstream optical port | P2CA: 2 Ports Per Board |
Service ports | |
GPON port | GPBD/GPBH: 8 Ports Per Board |
GPFD: 16 Ports Per Board | |
10G GPON port | XGBC: 4 Ports Per Board |
P2P GE optical port | OPGD/OPGE: Single-fiber bi-directional: 48 Ports Per Board, Two-fiber bi-directional: 24 Ports Per Board |
P2P FE optical port | OPFA: 16 Ports Per Board |
OPGD/OPGE: Single-fiber bi-directional: 48 Ports Per Board, Two-fiber bi-directional: 24 Ports Per Board | |
Ethernet optical port | ETHB: 8 Ports Per Board |
E1 port | H802EDTB: 16 Ports Per Board |
ADSL2+ | ADPD/ADQD/ADKM/ADPE/ADPM |
VDSL2 | VDRD |
VDMF/VDNF/VDJM/VCMM | |
VDPE/VDPM/VDQM/VDPD/VCPE | |
EFM SHDSL | SHLM |
SHGM | |
TDM SHDSL | H802EDTB: 16 Ports Per Board |
POTS | ASPB : 64 Ports Per Board |
ADSL2+&POTS | CAME : 48 Ports Per Board |
VDSL2&POTS | CVME : 48 Ports Per Board |
CCPE : 64 Ports Per Board | |
ISDN BRA | DSRD/DSRE :32 Ports Per Board |
Device Specifications | |
Dimensions (W x D x H, including mounting brackets) | ETSI Chassis: 530.00 mm x 275.80 mm x 447.20 mm |
IEC Chassis: 482.60 mm×275.80 mm×441.70 mm | |
Dimensions (W x D x H, excluding mounting brackets) | ETSI Chassis: 490.00 mm x 275.80 mm x 447.20 mm |
IEC Chassis: 442.00 mm×275.80 mm×441.70 mm | |
Maximum weight (including mounting brackets) | ETSI Chassis: 33 KG |
IEC Chassis: 30.54 KG | |
Working environment temperature | For an indoor cabinet Configured with 1 subrack: -25°C to +65°C Configured with 2 subracks: -25°C to +55°C |
Working environment humidity | 5% RH to 95% RH |
Atmosphere pressure | 61 kPa to 106 kPa |
Altitude | < 4000 m |